System 4
|
Price: Call for Configuration & Pricing
Manufacturer: Ametek Land Instruments
|
**NOTE: Due to the complexity of configuring this product, we ask that you call us at 866-451-2257 or 805-576-7625 for quotes and more information**
System 4 is a complete family of non-contact temperature monitoring systems designed to give you the flexibility and choice in both performance and price to meet your exact measurement requirements. Select from a range of processors, thermometers and mountings and accessories to suit your particular application.
PROCESSORS:
Landmark Graphic:
|
LANDMARK® GRAPHIC is a high precision, multi function, intelligent processor with graphical display. Two versions are available: a single channel and a multiple channel processor. The multiple channel version can be configured with up to four different thermometers. A simple to use multi-language menu enables the user to set-up the thermometer and process variables.
LANDMARK® GRAPHIC provides a complete range of thermometer signal conditioning functions including: peak picker, averager, track and hold, high/low alarms and 0 or 4 to 20mA and 1mV/° outputs from each thermometer channel.
Temperature is displayed as a deviation chart, line chart, numeric or mixed display.
Optional serial RS232C/RS485A communications is also available.
|
|
|
|
|
A new math function is available which simultaneously computes and outputs two additional values including: maximum, minimum, mean, difference, range and expanded span. Typical examples include: monitoring the temperature uniformity across a web or strip using an array of 4 thermometers; expanded span which combines the minimum and maximum temperature ranges of up to 4 different thermometers; and difference where two thermometers are monitoring the same target spot.
| Accuracy:
|
0.12% reading
|
| Outputs:
|
0 or 4 to 20mA and 1mV/°
|
| Peak Picker:
|
0, 0.25, 0.5, 1, 2, 4, 8, 16, 32, 64, 128, 256, 512°/s decay rate
|
| Averager:
|
0, 0.25, 0.5, 1, 2, 4, 8, 16, 32, 64, 128, 256, 512s time constant
|
| Track and Hold:
|
10ms response time
|
| Alarms:
|
High or low
|
Landmark Classic:
|
LANDMARK® CLASSIC is a lower cost, modular thermometer signal processor, providing a large digital display of temperature, emissivity/non greyness and alarm settings.
LANDMARK® CLASSIC provides a 4 to 20mA output for monitoring, recording or control. Optional plug-in time functions - either peak picker or averager - and alarm modules maximize the capabilities and flexibility of the system.
|
| Accuracy:
|
0.2% reading
|
| Peak Picker (optional):
|
0.05 to 25% of span/s
|
| Averager (optional):
|
0.1 to 60s
|
| Alarms (optional):
|
High or low
|
| PROCESSOR TYPE
|
ALARM 1
|
ALARM 2
|
TIME FUNCTION
|
| LMC-0-0-0
|
-
|
-
|
-
|
| LMC-A-0-0
|
YES
|
-
|
-
|
| LMC-A-A-0
|
YES
|
YES
|
-
|
| LMC-0-0-P
|
-
|
-
|
PEAK PICKER
|
| LMC-0-0-A
|
-
|
-
|
AVERAGER
|
| LMC-A-0-P
|
YES
|
-
|
PEAK PICKER
|
| LMC-A-0-A
|
YES
|
-
|
AVERAGER
|
| LMC-A-A-P
|
YES
|
YES
|
PEAK PICKER
|
| LMC-A-A-P
|
YES
|
YES
|
AVERAGER
|
Landmark Profibus:
|
LANDMARK® for Profibus is a high precision, digital, DIN-rail mounted signal processing unit, providing economic integration of any System 4 thermometer within a Profibus network - ideal for both OEM and end user applications.
LANDMARK® for Profibus (LMP) is an intelligent microprocessor-based thermometer signal processor, designed for the ultimate in process temperature monitoring at low cost.
A complete range of thermometer signal conditioning functions is provided including: peak picker, averager, track and hold, and alarm outputs.
As well as its standard Profibus DP interface, LMP also provides additional analog connectivity for supplementary process integration via a 0 or 4 to 20mA output with user-selectable span, Hi/Lo alarm contacts and external control of peak-picker reset or track & hold reset via customer contact closure.
|
|
Features Include:
|
|
-
|
Profibus compatibility and connectivity
|
|
-
|
Standard DIN-rail, back of panel mounting
|
|
-
|
Time Functions - average, peak picker and track and hold as standard
|
|
-
|
Industry standard 0 or 4 to 20mA output
|
|
-
|
Emissivity/non-greyness adjustment
|
|
-
|
Alarm ready output
|
|
-
|
Optional LANDMARK indicator (LMi) and power supply (DPU) are also available
|
INFRARED THERMOMETERS:
| Model
|
Temp Range
|
Waveband
|
FOV
|
| Infrared Thermometer M1 - General purpose, metals, glass, refractories.
|
| M1 450/1000C
|
450 to 1000°C
|
1.0 µm
|
30:01:00
|
| M1 850/1850F
|
850 to 1850°F
|
1.0 µm
|
30:01:00
|
| M1 600/1600C
|
600 to 1600°C
|
1.0 µm
|
100:01:00
|
| M1 1100/2900F
|
1100 to 2900°F
|
1.0 µm
|
100:01:00
|
| M1 800/2600C
|
800 to 2600°C
|
1.0 µm
|
200:01:00
|
| M1 1500/4700F
|
1500 to 4700°F
|
1.0 µm
|
200:01:00
|
|
|
|
|
| Infrared Thermometer M2 - General purpose, metals & glass processing
|
| M2 300/1100C
|
300 to 1100°C
|
1.6 µm
|
100:01:00
|
| M2 600/2000F
|
600 to 2000°F
|
1.6 µm
|
100:01:00
|
|
|
|
|
| Infrared Thermometer M4 - Bright, UNO stand alone radiation thermometer oxidized/lightly oxidized metal surfaces
|
| M4 50/250C
|
50 to 250°C
|
2.4 µm
|
30:01:00
|
| M4 150/500F
|
150 to 500°F
|
2.4 µm
|
30:01:00
|
| M4 150/550C
|
150 to 550°C
|
2.4 µm
|
100:01:00
|
| M4 300/1000F
|
300 to 1000°F
|
2.4 µm
|
100:01:00
|
|
|
|
|
| Infrared Thermometer M5 - Glass surface temperature measurement
|
|
| M5 400/1300C
|
400 to 1300°C
|
4.8 to 5.2µm
|
100:01:00
|
| M5 750/2400F
|
750 to 2400°F
|
4.8 to 5.2µm
|
100:01:00
|
| M5 1000/2500C
|
1000 to 2500°C
|
4.8 to 5.2µm
|
100:01:00
|
| M5 1800/4500F
|
1800 to 4500°F
|
4.8 to 5.2µm
|
100:01:00
|
|
|
|
|
| Infrared Thermometer M6 - General purpose, low temp, metals, glass, food, paper, textiles
|
| M6 0/300C
|
0 to 300°C
|
3 to 5µm
|
30:01:00
|
| M6 50/600F
|
50 to 600°F
|
3 to 5µm
|
30:01:00
|
| M6 100/700C
|
100 to 700°C
|
3 to 5µm
|
30:01:00
|
| M6 200/1300F
|
200 to 1300°F
|
3 to 5µm
|
30:01:00
|
|
|
|
|
| Infrared Thermometer M7 - Plastic thin film temperature measurement
|
|
| M7 25/375C
|
25 to 375°C
|
3.43µm
|
30:01:00
|
| M7 75/700F
|
75 to 700°F
|
3.43µm
|
30:01:00
|
|
|
|
|
| Infrared Thermometer M8 - Food, textiles, paper, plastics, rubber, wood, paint & ceramics
|
| M8 0/1000C
|
0 to 1000°C
|
8 to 14µm
|
100:01:00
|
| M8 30/1830F
|
30 to 1830°F
|
8 to 14µm
|
100:01:00
|
|
|
|
|
| Ratio Thermometer R1 -Variable emissivity, obscuration of target, partially filled FOV
|
| R1 600/1600C
|
600 to 1600°C
|
0.85 to 1.1µm
|
50:01:00
|
| R1 1100/2900F
|
1100 to 2900°F
|
0.85 to 1.1µm
|
50:01:00
|
| R1 1000/2600C
|
1000 to 2600°C
|
0.85 to 1.1µm
|
200:01:00
|
| R1 1800/4700F
|
1800 to 4700°F
|
0.85 to 1.1µm
|
200:01:00
|
System 4 Fibroptic Thermometers
The System 4 Fibroptic thermometers offer a wide range of options in situations when targets are obscure/difficult to access
| Model
|
Temperature Range
|
Waveband
|
FOV
|
Head
|
|
| Fibroptic - Infrared Thermometer - M1 - General purpose, metals, glass, refractories.
|
M1 600/1600CL
M1 600/1600CYL
M1 1100/2900FL
M1 1100/2900FYL
|
600 to 1600°C
1100 to 2900°F
|
1.0µm
|
25:1
|
A10
A25
A50
|
|
|
M1 800/2600CL
M1 800/2600CYL
M1 1500/4700FL
M1 1500/4700FYL
|
800 to 2600°C
1500 to 4700°F
|
1.0µm
|
75:1
|
A10
A25
A50
|
|
|
| Fibroptic - Infrared Thermometer - M2 - General purpose, metals and glass processing.
|
M2 300/1100CL
M2 300/1100CYL
M2 600/2000FL
M2 600/2000FYL
|
300 to 1100°C
600 to 2000°F
|
1.6µm
|
25:1
|
A10
A25
A50
|
|
|
| Fibroptic - Infrared Thermometer - M3 - General purpose, low temperature secondary metals.
|
|
M3 50/250CQ
M3 150/500FQ
|
50 to 250°C
150 to 500°F
|
2.1µm
|
20:1
|
D10
D25
D50
|
|
|
| Fibroptic ratio radiation thermometer - R1 - Ratio thermometer, variable emissivity, obscuration of target, partially filled field of view.
|
R1 600/1600CL
R1 600/160CYL
R1 1100/2900FL
R1 1100/2900FYL
|
600 to 1600°C
1100 to 2900°F
|
0.85 to 1.1µm
|
25:1
|
A10
A25
A50
|
|
|
R1 1000/2600CL
R1 1000/2600CYL
R1 1800/4700FL
R1 1800/4700FYL
|
1000 to 2600°C
1800 to 4700°F
|
0.85 to 1.1µm
|
75:1
|
A10
A25
A50
|
|
Emissivity Enhancer
The Emissivity Enhancer improves the accuracy of System 4 short wavelength thermometers on difficult to measure materials such as bright annealed and stainless steel strip.
Intended for use on low emissivity materials it gives enhanced emissivity values at a distance of 30mm/1.2in from the target surface.
MOUNTINGS & ACCESSORIES:
**NOTE: Due to the complexity of configuring this product, we ask that you call us at 866-451-2257 or 805-576-7625 for quotes and more information**
|
|
|
|
Product Reviews
|
Now Accepting
Or Fax Purchase Order To
(805) 576-7629
|
|